CONDUCTOR
Stranded bare copper conductor class 2 (IEC 60228) (tinned conductor and class 5 formation, on request)
INSULATION
XLPE
LAY-UP
Cores are paired or triad
PAIR IDENTIFICATION
Black-light blue numbered
OVERALL SCREEN
Aluminium polyester tape, with tinned copper drain wire 0,5mm2
INNER SHEATH
Thermoplastic Material LSZH
ARMOURING
Tinned or Bare Copper Wire Braid
OUTER SHEATH
SHF1
VOLTAGE RATING
60 V - 250 V
TEMP. RATING
- During operation: -20°C + 85°C
- During installation: -15°C + 60°C
MARKING
METALLURGICA BRESCIANA - YEAR-HF-OS-ATC- .....x...... mm2 V- IEC 332-3A
| CROSS SECTIONAL AREA mm2 | N° OF PAIRS | APPROX OVERALL DIAMETER mm | APPROX CABLE WEIGHT Kg/Km | MIN BENDING RADIUS mm |
MAX CONDUC. RESISTANCE AT 20°C OHM/Km | REACTANCE AT 50 Hz OHM/Km |
26 26 26 26 26 26 26 26 26 |
0,121 0,121 0,121 0,121 0,121 0,121 0,121 0,121 0,121 |
|||||
0,75 |
1 2 4 7 10 14 19 24 30 |
8,2 11,2 12,8 15,4 19,5 21,4 23,8 27,6 29,2 |
100 160 220 320 450 570 710 880 1040 |
50 68 77 93 117 129 143 166 176 |
Note: Different number of pairs and different sections are available on request Cables in triples are available on request.