Number x nominal diameter of wire
|
|
Thickness of insulation
|
Overall diameter
|
Conductor resistance at 20°C
|
||
| Min.
|
Max.
|
Min.
|
Min.
|
Max.
|
Max.
|
||
| mm²
|
mm
|
|
|
mm
|
mm
|
mm
|
Ω/Km
|
|
19x0,18
|
0,80
|
0,95
|
0,18
|
1,15
|
1,45
|
40,1
|
0,75
|
37x0,16 (a)
|
1,00
|
1,15
|
0,18
|
1,35
|
1,65
|
26,7
|
1,0
|
37x0,18 (a)
|
1,10
|
1,30
|
0,18
|
1,45
|
1,80
|
20,0
|
1,5
|
37x0,23 (a)
|
1,45
|
1,65
|
0,22
|
1,95
|
2,30
|
13,7
|
| 2,5
|
37x0,30 (a) | 1,85
|
2,15 | 0,28
|
2,50
|
2,85
|
8,21
|
This table should be used for the single core cables, and read in conjunction with other tables for multicore cables
CONSTRUCTION
CONDUCTOR
Tin-coated annealed copper.
INSULATION
Double layer of cross linked polyolefin as defined in EN 50306-1
LAYING-UP (only for multicore cables)
The cores of multicore cables are twisted together.
Cores distinction by colours and numbers.
METALLIC BRAID SCREENING (only for screened cables):
The screen shall consist of a tinned copper wire braid,
with nominal wire diameter ³ 0,10 mm.
SHEATH
EM 104 compound in accordance with EN 50264-1
EXTRA OIL AND FUEL RESISTANT
OPERATING TEMPERATURE (Single core): -40 +105 °C
OPERATING TEMPERATURE (Multi cores): -40 +90 °C
REFERENCE STANDARDS: EN 50306-1:2002 – EN 50306-2:2002 – EN 50306-3:2002 - EN 50306-4:2002