THIN WALL - 300 V



 

REQUIREMENTS FOR CONSTRUCTION

Nominal cross-sectional area Number x nominal diameter of wire Diameter Thickness of insulation Overall diameter Conductor resistance at 20°C
Min. Max. Min. Min. Max. Max.
mm² mm mm mm mm mm mm Ω/Km

0,5

19x0,18

0,80

 

0,95

 

0,18

 

1,15

 

1,45

 

40,1

 

0,75

37x0,16 (a)

 

1,00

 

1,15

 

0,18

 

1,35

 

1,65

 

26,7

 

1,0

37x0,18 (a)

 

1,10

 

1,30

0,18

 

1,45

 

1,80

 

20,0

 

1,5

37x0,23 (a)

 

1,45

 

1,65

 

0,22

 

1,95

 

2,30

 

13,7

 

2,5 37x0,30 (a) 1,85 2,15 0,28 2,50 2,85 8,21

(a) = this cable may be supplied in 19 strand conductor providing all product performance requirements in the specification are met


This table should be used for the single core cables, and read in conjunction with other tables for multicore cables



CONSTRUCTION                                                                                                                     


CONDUCTOR   
       

Tin-coated annealed copper.


INSULATION

Double layer of cross linked polyolefin as defined in EN 50306-1


LAYING-UP (only for multicore cables)

The cores of multicore cables are twisted together.
Cores distinction by colours and numbers.

 

METALLIC BRAID SCREENING (only for screened cables):

The screen shall consist of a tinned copper wire braid,
with nominal wire diameter
³ 0,10 mm.


SHEATH

EM 104 compound in accordance with EN 50264-1

 

EXTRA OIL AND FUEL RESISTANT

OPERATING TEMPERATURE (Single core): -40 +105 °C

OPERATING TEMPERATURE (Multi cores): -40 +90 °C


 REFERENCE STANDARDS:  EN 50306-1:2002 – EN 50306-2:2002 – EN 50306-3:2002 - EN 50306-4:2002



The data included in the present catalogue are merely indicative; Metallurgica Bresciana S.p.A. reserves to itself the right to change them at its own discretion and in any moment.
© Metallurgica Bresciana S.p.A. Manufacturer of Precision Special Electric Cables and Optical Fibre Cables