REQUIREMENTS FOR CONSTRUCTION
| Nominal cross-sectional area
|
Number x nominal diameter of wire
|
Diameter
|
Thickness of insulation
|
Overall diameter
|
Conductor resistance at 20°C
|
||
| min | max | min | min | max | max | ||
| mm²
|
mm | mm | mm | mm | mm | mm | Ω·km |
0,5
0,75
1,0
1,5
2,5
|
19x0,18
37x0,16 (a)
37x0,18 (a)
37x0,23 (a)
37x0,30 (a)
|
0,80
1,00
1,10
1,45
1,85
|
0,95
1,15
1,30
1,65
2,15
|
0,18
0,18
0,18
0,22
0,28
|
1,15
1,35
1,45
1,95
2,50 |
1,45
1,65
1,80
2,30
2,85 |
40,1
26,7
20,0
13,7
8,21
|
(a) = this cable may be supplied in 19 strand conductor providing all product performance requirements in the specification are met
MULTICORE CABLES, SCREENED AND STANDARD WALL SHEATHED (EM 104)
CLASS E:
CLASS P: Protected situation
| Number of cores and nominal cross section
|
CLASS E | CLASS P |
||||
| Minimum thickness of sheath
|
Overall diameter
|
Minimum thickness of sheath
|
Overall diameter
|
|||
| Min.
|
Max.
|
Min.
|
Max.
|
|||
| mm²
|
mm | mm | mm | mm | mm | mm |
2x0,5
3x0,5
4x0,5
6x0,5
8x0,5
|
1,0
1,0
1,0
1,0
1,0
|
5,7
6,1
6,9
7,5
|
6,5
6,7
7,1
7,9
8,5
|
0,42
0,42
0,42
0,42
|
4,1
4,3
4,7
5,5
6,0
|
5,3
5,7
6,5
7,0
|
2x0,75
3x0,75
4x0,75
6x0,75
8x0,75
|
1,0
1,0
1,0
1,0
1,0
|
6,2
6,5
7,5
8,2
|
6,9
7,2
7,5
8,5
9,2
|
0,42
0,42
0,42
0,42
0,42
0,42 |
4,5
4,7
5,2
6,1
6,6
|
5,7
6,2
7,1
7,6
|
2x1,0
3x1,0
4x1,0
6x1,0
8x1,0
|
1,0
1,0
1,0
1,0
1,0
|
6,5
6,9
8,0
8,6
|
7,2
7,5
7,9
9,0
9,8
|
0,42
0,42
0,42
0,42
0,42
|
4,7
5,1
5,5
6,6
7,7
|
6,0
6,5
7,6
8,7
|
2x1,5
3x1,5
4x1,5
6x1,5
8x1,5
|
1,0
1,0
1,0
1,0
1,0
|
7,1
7,4
8,0
9,2
10,2
|
8,1
8,4
9,0
10,4
11,4
|
0,42
0,42
0,42
0,56
0,56
|
5,7
6,0
6,6
8,3
8,9
|
7,0
7,6
9,3
10,1
|
2x2,5
3x2,5
4x2,5 |
1,0
1,0
1,0
|
8,6
9,4 |
9,8
10,6 |
0,56
0,56
0,56
|
7,3
7,7
8,4
|
8,7
9,6
|