CONDUCTOR
Solid/stranded bare copper wires.
INSULATION
PE
LAY-UP
Cores are paired, pairs are twisted in reverse layer technique forming a concentric cable.
COLOUR CODE
Refer to table 1 for Colour Code.
INDIVIDUAL SCREEN
Aluminium-backed polyester tape, with tinned copper drain wire 0,5 mm2
WRAPPING
Polyester binder tape.
COLLECTIVE SCREEN
Aluminium-backed polyester tape, with tinned copper drain wire 0,5 mm2
INNER SHEATH
PE
ARMOURING
Single layer of steel wires (SWA)
OUTER SHEATH
PVC
RATED VOLTAGE
300/500 V r.m.s
TEST VOLTAGE
1000 V r.m.s for 1' between conductor, and between conductors and screen / armour
TEMP. RATING
- During operation: -30 °C + 70°C
- During installation: - 5°C + 50°C
| N° OF PAIRS | CROSS SECTIONAL AREA mm2 | NOMINAL INSULATION THICKNESS mm | DIAMETER OF ARMOUR WIRE mm | NOMINAL SHEATH THICKNESS mm |
APPROX OVERALL DIAMETER mm D | APPROX CABLE WEIGHT Kg/Km | MIN BENDING RADIUS = nxD |
| N | |||||||
13,5 17,5 22,2 25,5 27,5 32 |
340 590 870 1220 1450 1850 |
12 12 12 12 12 12 |
|||||
2 5 10 15 20 30 |
0,50 (1x0,80) | 0,50 0,50 0,50 0,50 0,50 0,50 |
0,9 1,25 1,25 1,6 1,6 1,6 |
1,4 1,5 1,7 1,7 1,8 1,9 |
|||
2 5 10 15 20 30 |
0,50 (16x0,20) | 0,60 0,60 0,60 0,60 0,60 0,60 |
0,9 1,25 1,6 1,6 1,6 2 |
1,5 1,6 1,8 1,8 1,9 2,1 |
15,5 19,2 25,5 28,6 31,1 37,2 |
400 660 1100 1350 1600 2350 |
12 12 12 12 12 12 |
2 5 10 15 20 30 |
1,00 (1x1,13) | 0,60 0,60 0,60 0,60 0,60 0,60 |
0,9 1,25 1,6 1,6 2 2 |
1,5 1,6 1,8 1,9 2 2,2 |
16,3 20,5 27 30,7 35,2 41 |
460 760 1300 1670 2290 2970 |
12 12 12 12 12 12 |
2 5 10 15 20 30 |
1,50 (7x0,53) | 0,60 0,60 0,60 0,60 0,60 0,60 |
1,25 1,6 1,6 2,00 2,00 2,5 |
1,6 1,7 1,9 2 2,1 2,4 |
19,1 23,9 31,3 36,4 40 50,2 |
660 1080 1660 2370 2800 4080 |
12 12 12 12 12 12 |
Note: Cables with higher or different number of pairs are available.