CONDUCTOR
Stranded bare copper wires
INSULATION
PVC
LAY-UP
Cores are paired, pairs are twisted in reverse layer technique forming a concentric cable. 2 pair cables are twisted in a star quad formation.
COLOUR CODE
Black-white with black cores numbered for pairs identification
WRAPPING
Polyester binder tape
COLLECTIVE SCREEN
Aluminium-backed polyester tape, with tinned copper drain wire 0,5 mm2
OUTER SHEATH
PVC
RATED VOLTAGE
300/500 V r.m.s
TEST VOLTAGE
1000 V r.m.s for 1' between conductor, and between conductors and screen / armour
TEMP. RATING
- During operation: -30 °C + 70°C
- During installation: - 5°C + 50°C
| N° OF PAIRS | CROSS SECTIONAL AREA mm2 | NOMINAL INSULATION THICKNESS mm | NOMINAL SHEATH THICKNESS mm |
APPROX OVERALL DIAMETER mm D | APPROX CABLE WEIGHT Kg/Km | MIN BENDING RADIUS = nxD |
| N | ||||||
6,00 6,80 9,80 1,75 15,60 17,25 21,60 25,00 |
50 68 115 170 275 355 500 740 |
10 10 10 10 10 10 10 10 |
||||
1 2 4 6 12 16 24 36 |
0,50 | 0,50 0,50 0,50 0,50 0,50 0,50 0,50 0,50 |
1,00 1,00 1,00 1,10 1,20 1,20 1,30 1,50 |
|||
1 2 4 6 12 16 24 36 |
0,75 | 0,60 0,60 0,60 0,60 0,60 0,60 0,60 0,60 |
1,00 1,00 1,00 1,10 1,20 1,30 1,30 1,50 |
6,80 7,80 11,40 13,70 18,40 20,60 25,60 29,70 |
62 90 155 235 390 500 720 1050 |
10 10 10 10 10 10 10 10 |
1 2 4 6 12 16 24 36 |
1,00 | 0,60 0,60 0,60 0,60 0,60 0,60 0,60 0,60 |
1,00 1,00 1,00 1,10 1,30 1,30 1,50 1,50 |
7,20 8,30 12,20 14,70 19,90 22,70 27,80 31,90 |
70 105 180 280 480 625 900 1300 |
10 10 10 10 10 10 10 10 |
1 2 4 6 12 16 24 36 |
1,50 | 0,60 0,60 0,60 0,60 0,60 0,60 0,60 0,60 |
1,10 1,10 1,10 1,10 1,30 1,50 1,70 2,00 |
8,00 9,20 13,50 16,20 21,90 24,50 31,50 36,40 |
88 135 240 360 630 850 1235 1830 |
10 10 10 10 10 10 10 10 |