CONDUCTOR
Stranded bare copper wires
INSULATION
XLPE
LAY-UP
Cores are paired, pairs are twisted in reverse layer technique forming a concentric cable.
COLOUR CODE
Black-white with black cores numbered for pairs identification
INDIVIDUAL SCREEN
Aluminium-backed polyester tape, with tinned copper drain wire 0,5 mm2
WRAPPING
Polyester binder tape
COLLECTIVE SCREEN
Aluminium-backed polyester tape, with tinned copper drain wire 0,5 mm2
OUTER SHEATH
PVC
RATED VOLTEGE
300/500 V r.m.s
TEST VOLTAGE
1000 V r.m.s for 1' between conductor, and between conductors and screen / armour
TEMP. RATING
- During operation: -30 °C + 70°C
- During installation: - 5°C + 50°C
| N° OF PAIRS | CROSS SECTIONAL AREA mm2 | NOMINAL INSULATION THICKNESS mm | NOMINAL SHEATH THICKNESS mm | APPROX OVERALL DIAMETER mm D |
APPROX CABLE WEIGHT Kg/Km | MIN BENDING RADIUS = nxD |
| N | ||||||
92 140 210 350 450 650 950 |
10 10 10 10 10 10 10 |
|||||
2 4 6 12 16 24 36 |
0,50 | 0,50 0,50 0,50 0,50 0,50 0,50 0,50 |
1,10 1,10 1,10 1,20 1,20 1,30 1,50 |
9,50 10,90 12,90 17,20 19,10 23,90 27,80 |
||
2 4 6 12 16 24 36 |
0,75 | 0,60 0,60 0,60 0,60 0,60 0,60 0,60 |
1,10 1,10 1,10 1,20 1,30 1,50 1,70 |
10,90 12,50 15,00 20,00 22,90 28,90 33,50 |
115 180 270 455 600 880 1295 |
10 10 10 10 10 10 10 |
2 4 6 12 16 24 36 |
1,00 | 0,60 0,60 0,60 0,60 0,60 0,60 0,60 |
1,20 1,20 1,30 1,30 1,30 1,50 1,70 |
11,90 13,80 16,50 22,00 24,50 31,00 36,00 |
135 215 330 545 715 1035 1535 |
10 10 10 10 10 10 10 |
2 4 6 12 16 24 36 |
1,50 | 0,60 0,60 0,60 0,60 0,60 0,60 0,60 |
1,20 1,30 1,30 1,50 1,50 2,00 2,00 |
13,00 15,50 18,50 24,50 27,20 35,30 40,50 |
165 275 415 720 945 1415 2040 |
10 10 10 10 10 10 10 |