CONDUCTOR
Stranded bare copper wires.
INSULATION
Double layer: Mica Tape + XLPE
LAY-UP
Cores are paired, pairs are twisted in reverse layer technique forming a concentric cable. 2 pair cables are twisted in a star quad formation.
COLOUR CODE
Black-white with black cores numbered for pairs identification
WRAPPING
Polyester binder tape.
COLLECTIVE SCREEN
Aluminium-backed polyester tape, with tinned copper drain wire 0,5 mm2
OUTER SHEATH
PVC
RATED VOLTAGE
300/500 V r.m.s
TEST VOLTAGE
1000 V r.m.s for 1' between conductor, and between conductors and screen
TEMP. RATING
- During operation: -30 °C + 70°C
- During installation: - 5°C + 50°C
| N° OF PAIRS | CROSS SECTIONAL AREA mm2 | NOMINAL INSULATION THICKNESS mm | NOMINAL SHEATH THICKNESS mm |
APPROX OVERALL DIAMETER mm D | APPROX CABLE WEIGHT Kg/Km | MIN BENDING RADIUS = nxD |
| N | ||||||
6,60 7,50 10,80 12,80 17,00 18,80 23,80 |
55 75 125 180 290 370 520 |
10 10 10 10 10 10 10 |
||||
1 2 4 6 12 16 24 |
0,50 | 0,50 0,50 0,50 0,50 0,50 0,50 0,50 |
1,00 1,00 1,00 1,10 1,20 1,20 1,30 |
|||
1 2 4 6 12 16 24 |
0,75 | 0,60 0,60 0,60 0,60 0,60 0,60 0,60 |
1,00 1,00 1,00 1,10 1,20 1,30 1,30 |
7,80 8,50 12,20 15,30 20,50 23,00 28,50 |
66 95 160 250 395 530 700 |
10 10 10 10 10 10 10 |
1 2 4 6 12 16 24 |
1,00 | 0,60 0,60 0,60 0,60 0,60 0,60 0,60 |
1,00 1,00 1,00 1,10 1,30 1,30 1,50 |
8,20 9,10 13,50 16,50 21,80 24,00 29,50 |
72 110 190 285 500 630 900 |
10 10 10 10 10 10 10 |
1 2 4 6 12 16 24 |
1,50 | 0,60 0,60 0,60 0,60 0,60 0,60 0,60 |
1,10 1,10 1,10 1,10 1,30 1,50 1,70 |
9,00 10,20 13,50 14,50 23,00 26,50 34,00 |
95 145 255 380 650 880 1350 |
10 10 10 10 10 10 10 |