Cables for industrial applications

SINGLE CORE CABLES ul 3266-3271-3272 APPROVED FOR 125°C OPERATING TEMPERATURE

dynax-uc
Cables for industrial applications

CONSTRUCTION

CONDUCTOR

Tinned copper, stranded. a for IEC 228 cl.5.

INSULATION

Special e-beam crosslinked polyolefin (XLPO).

Colours: black, grey, blue, red, brown, green, yellow.

MAIN DATA FOR UL 3266 CABLES -300 V

CROSS SECTION CONDUCTOR DIAMETER CROSS SECTION CONDUCTOR RESISTANCE AT 20°C MIN INSULATION THICKNESS OUTER DIAMETER WEIGHT
max g/m
AWG n x Фmm mm2 max mm
Ω/km mm

26

24

22

20

18

16

14

19x0,10

19x0,13

19x0,16

19x0,20

19x0,25

19x0,30

19x0,38

0,13

0,20

0,32

0,52

0,87

1,31

2,08

140

87,6

55,4

34,6

21,8

13,7

8,62

0,381

0,381

0,381

0,381

0,381

0,381

0,381

1,40

1,50

1,70

1,90

2,20

2,40

2,90

2,5

4

5

8

11

16

21

 

 

MAIN DATA FOR UL 3271/3272 CABLES -600 V

CROSS SECTION CONDUCTOR DIAMETER CROSS SECTION CONDUCTOR RESISTANCE AT 20°C MIN INSULATION THICKNESS OUTER DIAMETER WEIGHT
max g/m
AWG n x Фmm mm2 max mm
Ω/km mm

26

24

22

20

18

16

14

19x0,10

19x0,13

19x0,16

19x0,20

19x0,25

19x0,30

19x0,38

0,13

0,20

0,32

0,52

0,87

1,31

2,08

140

87,6

55,4

34,6

21,8

13,7

8,62

0,76

0,76

0,76

0,76

0,76

0,76

0,76

2,20

2,35

2,50

2,70

3,00

3,30

3,70

7

8

10

13

17

22

33

Approval : UL 3266 - CSA 1 A/B (cables with rated voltage 300V)

Approval : UL 3271 - UL 3272 - CSA 1 A/B (cables with rated voltage 600V)

Insulation constant : 1200 M Ω/km min

Operating tenperature : -40 +125°C

Halogenhydric gasses content (IEC 60754-1): 0%

Degree of acidity of gasses (IEC 60754-2) :

- Acidity : pH 4,3 min

- Conductivity: 10 αS/mm max

Smoke optical density (IEC61034) : 1 max

Flame retardancy : VW-1

 

 

 

 

 


The data contained in this catalogue is merely indicative.Metallurgica bresciana S.p.A. reserves the right to modify such data at its own discretion.
© Metallurgica Bresciana S.p.A. Manufacturer of Precision Special Electric Cables and Optical Fibre Cables