CONSTRUCTION
CONDUCTOR
Tinned copper, flexible a for IEC 228 cl.5.
INSULATION
Special e-beam crosslinked polyolefin (XLPO). Colour : black (single core), black and blue (two cores).
VAPOUR BARRIER (single core cables)
TNT tape plus polyester tape, PE coated, thermally bonded to the outer jacket.
JACKET
Special e-beam crosslinked polyolefin (XLPO). Colour : black, red, white, blue, green, brown, green/yellow (single core cables), black (two core cables).
| COMPOSITION | CONDUCTOR DIAMETER | CONDUCTOR RESISTANCE AT 20°C | INSULATION DIAMETER | OUTER DIAMETER | WEIGHT | MINIMUM BENDING RADIUS | ||
| gr/mt | mm | |||||||
| n x mm2 | mm | Ω/km | mm | mm | ||||
1x2,5 1x4 1x6 1x10 1x16 2x4 2x6 2x10 2x16 |
2,05 2,6 3,1 4,1 5,4 2,6 3,1 4,1 5,4 |
8,21 5,09 3,39 1,95 1,24 5,09 3,39 1,95 1,24 |
3,95 4,65 5,35 6,65 8,05 4,65 5,35 6,65 8,05 |
±0,15 ±0,15 ±0,15 ±0,15 ±0,15 ±0,15 ±0,15 ±0,15 ±0,15 |
5,95 6,65 7,35 8,65 10,05 10,85 12,25 15,55 17,65 |
±0,15 ±0,15 ±0,15 ±0,15 ±0,15 ±0,15 ±0,15 ±0,15 ±0,15 |
52 72 100 160 220 167 220 360 485 |
58 65 72 85 99 107 121 154 175 |
Operating voltage (Uο/U): 600/1000V
Test voltage : 4000V c.a.
Operating temperature : -55+ 145°C (fixed lay)
Operating temperature : -35+ 120°C (mobile lay)
Insulation resistance at 30°C: 3,3 10(13) Ω/cm
Abrasion resistance : very good
Flexibility : good
Ozone resistance : DIN VDE 0472 T805 Part A
Flame retardancy : IEC 60332-3-24 C
Halogenhydric gasses emission : IEC 60754-1
Smoke optical density : IEC 61034/1-2
Resistance to SAE20 oil : VDE 0472 T803