CONSTRUCTION
CONDUCTOR
Tinned copper, stranded, as for IEC 228 cl.5
INSULATION
Special e-beam crosslinked polyolefin (XLPO).
Colours: black, grey, blue, red, brown, green, yellow.
MAIN DATA FOR UL 3289 CABLES - 600V
| CROSS SECTION | CONDUCTOR CONSTRUCTION | CROSS SECTION | CONDUCTOR RESISTANCE AT 20°C | MIN. INSULATION THICKNESS | OUTER DIAMETER | WEIGHT | |
| max | g/m | ||||||
| AWG | n x Фmm | mm2 | max | mm | |||
| Ω/km | mm | ||||||
26 24 22 20 18 16 14 12 |
19x0,10 19x0,13 19x0,16 19x0,20 19x0,25 19x0,30 19x0,38 37x0,35 |
0,13 0,20 0,32 0,52 0,87 1,31 2,08 3,31 |
140 87,6 55,4 34,6 21,8 13,7 8,62 5,43 |
0,76 0,76 0,76 0,76 0,76 0,76 0,76 0,76 |
2,20 2,35 2,50 2,70 3,00 3,30 3,70 4,20 |
7 8 9 12 16 21 29 43 |
|
Approval : UL 3289
Insulation constant : 1000 M Ω/km min
Operating temperature : -40 + 150°C
Flame retardancy : VW -1